Foam eductor psi
WebAkron Brass 250 GPM Pyrolite In-Line Foam EductorThe Akron Brass 250 GPM Pyrolite In-Line Foam Eductor features a large, easy to read, and removable metering dial with infinite settings between 0% and 6%. The Eductors are rated to flow at 200 psi (14... WebNov 8, 2024 · The foam eductor needs to be set to the proper percentage for foam solution added. At the top of the eductor is a dial which allows the user to select the proper …
Foam eductor psi
Did you know?
Webas 70 psi (4.8 bar), these eductors are typically used with inlet pressures greater than 100 psi (6.9 bar) in order to generate discharge pressures adequate for effective firefighting. … WebStandard inlet operating pressure is 200 psi (13.8 bar) on 125 Series eductors. Custom designs are also available with inlet operating pressures of 160 psi (11 bar) and 145 psi (10 bar). ... All the foam passageways can easily be inspected. The foam passageway into the eductor contains a free-fl oating check disk with three fi ns. The check ...
WebThis is the finished foam produced from 9-gallons of FireAde2000 AFFF concentrate applied at 6% through a foam eductor. Supply the eductor with 200-psi. Station 34-A. 882K views WebSep 12, 2024 · If the eductor manufacturer's recommendations for inlet pressure, maximum hose length and size are followed, the automatic nozzle will adjust itself automatically to …
WebOct 1, 1997 · Rule 3: Foam solution concentration is correct only at the rated inlet pressure of the eductor, usually 150 to 200 psi (1,050 kPa to 1,400 kPa). Using eductor inlet pressures lower than the rated ... WebINLINE FOAM INDUCTOR TECHNICAL DATA MODEL IG - Bronze material IS - Stainless Steel material OPERATING 6.5 to 12 bar PRESSURE (93 - 175 psi) FACTORY 25 bar (365 psi) HYDROSTATIC TEST PRESSURE SUITABLE FOAM 3% AFFF or 3% x 3% AR-AFFF MAXIMUM BACK 65% of Inlet Pressure PRESSURE FLANGE ANSI B16.5 Class 150# …
WebJun 1, 2006 · Eductors have an inlet pressure rating, usually 200 psi, and a flow rating, such as 95 or 125 gpm, where the particular device is designed to operate. All eductors …
Web- Built-in by-pass chamber, allows the operator to change from water to foam without shutting down - Large, easy to read, and removable metering dial with settings between 0% and 6%. Detents at 1/4, 1/2, 1, 3 and 6% - … recreation professionals week 2023WebElkhart Brass - Fire Fighting Equipment recreation professorWebAll controls are easy to use with gloves. They are made of hard-coat anodized aluminum for corrosion protection. The required inlet pressure is 200 psi. The maximum allowable back pressure is 130 psi. Technical Data recreation professionals of ontarioWebAFFF Inline Eductor • Needs a minimum of 100 psi firemain to produce a 6% foam discharge. • Teflon backflow ball must be in place. • Screens must be in the pick up tubes crows foot and in the backflow housing. recreation program planning templateWebAn eductor is a piece of equipment that introduces foam concentrate into your water stream. In the device, water enters an inlet and moves through a tapered section. It then moves through a small orifice and into a bigger … recreation programmingWebJun 30, 2007 · Most Class B foams we see are "film forming" and have two actions they can use: foam blanket and film forming. A few only use the foam blanket. Film forming won't matter whether you're using a 100psi nozzle, 75psi, smoothbore, open butt, whatever. HOWEVER, the film is easily broken by protrusions -- such as brush or tall grass on a … recreation programs examplesupcea teaching award